Đăng nhập
 
Tìm kiếm nâng cao
 
Tên bài báo
Tác giả
Năm xuất bản
Tóm tắt
Lĩnh vực
Phân loại
Số tạp chí
 

Bản tin định kỳ
Báo cáo thường niên
Tạp chí khoa học ĐHCT
Tạp chí tiếng anh ĐHCT
Tạp chí trong nước
Tạp chí quốc tế
Kỷ yếu HN trong nước
Kỷ yếu HN quốc tế
Book chapter
Tạp chí quốc tế 2024
Số tạp chí 71(2024) Trang: e128139
Tạp chí: Pharmacia

Vancomycin is a critical antibiotic frequently utilized in clinical settings, with therapeutic drug monitoring (TDM) strongly advised to optimize treatment efficacy and mitigate the risk of adverse effects. However, current methods for measuring vancomycin levels in human plasma are hindered by long analysis times and complicated sample preparations. Thus, this study developed and validated a novel UPLC-MS/MS method for a rapid (with a running time of 3.5 min) and simple analysis of plasma vancomycin. To quantify vancomycin concentration in human plasma, we have developed and validated the UPLC-MS/MS method with high sensitivity, specificity, and accuracy, meeting the strict criteria according to the Food and Drugs Administration (FDA) guidelines for validation biological analysis methods. Vancomycin and atenolol (internal standard) underwent positive electrospray ionization (ESI+) and detection in multi-reaction monitoring (MRM) mode. The selected MRM transitions were m/z 725.66→144.16 for vancomycin and m/z 267.29→189.96 for atenolol. Plasma samples were precipitated using a simple mixture containing acetonitrile, methanol, and formic acid as a pH adjuster. The separation was performed using the Poroshell 120 Phenyl Hexyl Column (4.6 × 150 mm, 2.7 μm) maintained at 25 °C for 3.5 min. Isocratic elution with a mobile phase (methanol and 0.1% formic acid in a 40:60 v/v ratio) at a flow rate of 0.5 mL/min was employed. The method showed linearity (0.1–75 μg/mL) with a coefficient of determination above 0.9994 and a lower limit of quantification at 0.1 μg/mL. Precision, both intraday and interday, was below 10%, and accuracy ranged from 91.70% to 111.57%. System suitability, selectivity, stability, carryover, dilution, recovery, and matrix effect validation results all met acceptable criteria. The established UPLC-MS/MS method is expected to be a rapid, simple, and reliable tool for drug monitoring and pharmacokinetic studies, enhancing patient care during vancomycin administration.

Các bài báo khác
Số tạp chí 14(2024) Trang: 427-432
Tạp chí: International Journal of Energy Economics and Policy
Số tạp chí 8(2024) Trang: 89-110
Tạp chí: Instructed Second Language Acquisition
Số tạp chí 10(2024) Trang: 68-79
Tạp chí: Street Art and Urban Creativity Scientific Journal
Số tạp chí 23(2024) Trang: 39-58
Tạp chí: International Journal of Learning, Teaching and Educational Research
Số tạp chí 19(2024) Trang: 1-13
Tạp chí: Model Assisted Statistics and Applications


Vietnamese | English






 
 
Vui lòng chờ...